  • 4(1706151899466).jpg

FA-L Series Weighing Module For Coal

FA-L Series

For customised ranges, accuracy, dimensions and other parameters, please contact us.

Request For Quote

Industry specific  products developed through deep customization based on the characteristics and needs of the coal quality analysis industry Adopt  new  super  monolithic  sensor  technology  -accurate, fast,stable and reliable.
● Sensitivity:unparalleled sensor design and processing technology ensure the sensitivity of micro-weighting results
● Precision:Particular super monolithic sensor technology ensures the accuracy,stability and consistency of weighing results.
 High-Speed:The sensor technology of horizontal bar,combined with excellent circuit design and software algorithm,meets the requirements of rapid weighing in the laboratory High-precision weighing modules,tailored to meet the needs of equipment or automated weighing system integration
● Accurate weighing and fast response;the excellent monolithic sensor enables fast and accurate weighing to be perfectly realized,and at the same time greatly reduces the influence of temperature drift on the results,achieving extremely high reliability of results.
● The isoCAL automatic internal calibration and adjustment function is adopted to fully ensure the accuracy of weighing results.Fully automatic temperature and time-triggered calibration and adjustment functions ensure that you can obtain accurate weighing results at any time and at any temperature.
● Compact structure,easy to install.The compact layout design can meet the space requirements of equipment and automatic weighing integrated system to the greatest extent possible.
● The four-level anti-vibration technology meets your various weighing environments.Users can choose your corresponding weighing environment according to the use environment,and realize accurate and fast weighing in the corresponding environment.
● Maximum safety protection level;dust-proof,waterproof,anti-gas corrosion
design,not only can improve the accuracy of weighing,but also greatly improve the service life of the sensor.360°safe overload protection to avoid damage to     the sensor during installation and use.
 

    FA-L55MZ  FA-L105-MZ  FA-L205-MZ FA-L124-MZ FAL224-MZ FA-L323-MZ FA-L523-MZ FA-L623i-MZ
Readability(d) mg 0.01 0.01 0.01 0.1 0.1 1 1 1
Max capacity(Max) g 51 120 220 120 220 320 520 620
    FA-L55-MZ  FA-L105-MZ  FA-L205-MZ FAL124-MZ FA-L224-MZ FA-L323-MZ FA-L523-MZ FA-L623-MZ
Readability(d)  mg 0.01 0.01 0.01 0.1 0.1 1 1 1
Max capacity(Max) g 51 120 220 120 220 320 520 620
Repeatability(at 5%load)                  
Typical value mg ±0.04 ±0.04 ±0.04 ±0.2 ±0.2 ±1.5  ±1.5  ±2.5 
Repeatability(at approx.100%load)                  
Typical value mg ±0.06 ±0.06 ±0.06 ±0.3  ±0.3 ±2.5 ±2.5  ±2.5 
Inearity deviation                  
Typical value mg ±0.05  ±0.05  ±0.05  ±0.3  ±0.3  ±2.5  ±2.5  ±2.5 
Sensitivity drift between(+10°℃~+30℃) ppm/K 5 5 5 5 5 5 5 5
Typical stabilization time s ≤2.5  ≤2.5  ≤2.5  ≤2.5  ≤2.5  ≤2.5  ≤2.5  ≤2.5 
Dimensions                  
L*W*H  mm 240.7*155*88.35
Weighing pan mm External calibration φ80 or custom Internal calibration φ36 or custom
Ambient condition                  
Input      DC24V+10%,0. 1A
IP Grade   IP54,IP65
Operation temperature   10℃~30℃
Humidity   30%~85%RH
Interface     RS232、RS485
Communication protocol   DAT232、DAT485(MODBUS)、custom
Note:ES-Lxxxi-Fully automatic internal calibration model ES-Lxxx-External calibration model

 

    FA-L1202-MZ   FA-L2202-MZ  FA-L3202-MZ FA-L5202-MZ
Readability(d) mg 10 10 10 10
Max capacity(Max)    g 1200 2200 3200 5200
Repeatability(at 5%load))          
Typical value  mg ±15 ±15 ±15 ±15
Repeatability(at   approx.100%load)           
Typical value    mg ±25 ±25 ±25 ±25
Linearity deviation          
Typical value mg ±25 ±25 ±25 ±25
Sensitivity drift between(+10°℃~+30℃) ppm/K 5 5 5 5
Typical stabilization time  s ≤2.5  ≤2.5  ≤2.5  ≤2.5
Dimensions            
L*W*H mm 240.7*155*88.35
Weighing pan  mm φ80 or Custom
Ambient condition     
Input   DC24V+10%,0.1A
IP Grade   IP54,IP65 
Operation temperature   10℃~30℃
Humidity   30%~85%RH
Interface      RS232、RS485
Communication  protocol       DAT232、DAT485(MODBUS)、Custom
Note:ES-Lxxxi-Fully automatic internal    calibration    model ES-Lxxx-External calibration model

 




 

 

 

 

 

 

 

 

 

 

Previous

Previous

Request For Quote

Register For Download

Kind reminder: Each user downloads once. If you need more information, please contact us