FA01A-A4 4 Channel Analog Amplifier 4-20mA

FA01A-A4

The amplifier is available in an aluminium housing. Weighing controllers are available in plastic, aluminium and explosion-proof housings to order. The weighing controller has built-in high performance devices, precision amplification line, internal voltage stabilisation of the line, constant current supply bridge, voltage and current conversion, impedance adaptation, linear compensation, temperature compensation, etc. The MV signal of the resistance-strain load cell is amplified into a standard current and voltage signal output of 4-20mA, 0-5V, etc., which can be received and processed directly with the control system such as the AD module of the peripheral PLC, the transmitter has The transmitter is equipped with the functions of external zero adjustment and external gain adjustment for standard signals.

For customised ranges, accuracy, dimensions and other parameters, please contact us.

Request For Quote

Product Features

A. Wide input range, 0.4~6mV/V can be matched with most strain bridge sensors
B. Four independent channels, strong load capacity can be connected with 16 350Ω sensors
C. Using imported electronic components with high response frequency and good long-term stability 
Comprehensive accuracy reaches ±0.05%FS
D. Input power reverse polarity protection and output short circuit protection
E. Power supply 18~30VDC (recommended 24VDC) or 15~22VAC

 

Technical Specifications

parameter Technical Indicators
Enter range 0.4~6mV/V
Comprehensive precision ≤0.1%F.S.
Sensor excitation voltage 5VDC±2%, 100mA
Power Supply DC:15V~30V
Enter load  350Ω 16 sensors
Rated output  0~±10V/4-20mA
Operating Temperature Range -30~60 C
Surroundings Temperature: -10~55℃ 
Storage: -25~65℃ 
Humidity: 35~85%RH 
Storage: 35~85%RH
Sample rate  ≥100HZ
Protection class  IP64

Product Dimensions

Installation size

 

 

Accurate measurement with matching display

The output of the force measuring and weighing sensor itself is an MV signal, which needs to be amplified and

convertedto display numerical values or output signals to the upper computer, PLC, etc.

 

 

 

Product Application

Applied to tank weighing, detection weighing, packaging equipment, lithium battery liquid injection machine equipment, etc.; mobile phone earphone hole, charging hole plugging force equipment , stress test of mobile phone buttons, screen, battery, etc. 3C testing equipment; new energy lithium battery formation machine pressure test, coating machine tension test; machine tool pressure test, bridge stress test, etc.

 