 nickinfo@fibos.cn  |     0086 18921011531

How To Calibrate An Omega Load Cell for Accurate Measurements?

Views: 222     Author: Tina     Publish Time: 2024-12-10      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Content Menu

Understanding Load Cells

>> Types of Load Cells

Importance of Calibration

Tools Required for Calibration

Step-by-Step Calibration Process

>> 1. Preparation

>> 2. Zero Balance Calibration

>> 3. One-Point Calibration

>> 4. Two-Point Calibration

>> 5. Multi-Point Calibration

Best Practices for Calibration

Troubleshooting Common Issues

Advanced Calibration Techniques

>> Dynamic Calibration

>> Software Calibration Tools

Conclusion

FAQ

>> 1. Why is regular calibration necessary for Omega load cells?

>> 2. What is the difference between one-point and two-point calibration?

>> 3. How often should I calibrate my Omega load cell?

>> 4. Can I perform calibration myself?

>> 5. What should I do if my readings are inconsistent after calibration?

Understanding Load Cells

Load cells are devices that convert a force into an electrical signal. They are widely used in weighing and measurement applications due to their accuracy and reliability. Omega load cells, in particular, are known for their high precision and durability.

Types of Load Cells

- Strain Gauge Load Cells: These measure the deformation (strain) of a material under load. They are the most common type of load cell used in various applications due to their accuracy and reliability.

- Hydraulic Load Cells: These use fluid pressure to measure load. They are often used in heavy-duty applications where high load capacities are required.

- Pneumatic Load Cells: These measure load based on air pressure. They are typically used in environments where electrical equipment may pose a hazard.

load cell calibration equipment1

Importance of Calibration

Calibration is the process of adjusting the output of a load cell to ensure it accurately reflects the applied force. Over time, factors such as mechanical wear, environmental conditions, and electrical interference can cause a load cell's readings to drift or become inaccurate. Regular calibration helps:

- Maintain measurement accuracy

- Extend the lifespan of the load cell

- Comply with industry standards

Tools Required for Calibration

Before starting the calibration process, gather the following tools:

- Calibration Weights: Known reference weights that are certified for accuracy.

- Digital Multimeter: For checking electrical parameters and ensuring proper connections.

- Calibration Certificate: A document that verifies the accuracy of your reference weights.

- Stable Surface: A flat, stable surface for mounting the load cell during calibration.

- Computer or Data Logger: For recording measurements and analyzing data.

Step-by-Step Calibration Process

1. Preparation

Before calibrating your Omega load cell, ensure that:

- The load cell is properly installed and secured.

- All connections are intact and free from damage.

- The environment is stable (temperature, humidity).

2. Zero Balance Calibration

Zero balance calibration ensures that the load cell reads zero when no load is applied. Follow these steps:

1. Remove any load from the load cell.

2. Access the calibration settings on your readout device or software.

3. Adjust the zero setting until the display reads zero.

This step is crucial because any offset can lead to significant errors in measurements.

3. One-Point Calibration

This basic method is suitable for applications requiring accuracy at a single load point.

1. Apply a known weight (e.g., 50% of full scale) to the load cell.

2. Record the output reading from the load cell.

3. Adjust the calibration settings to match the known weight.

One-point calibration is quick but may not account for non-linearities in measurement across different loads.

Calibrate Button Load Cell_3

4. Two-Point Calibration

For improved accuracy across a range of loads, perform a two-point calibration.

1. Set the first point at zero (as done in zero balance).

2. Apply a second known weight (e.g., full scale).

3. Record both outputs and adjust settings accordingly.

This method provides better linearity than one-point calibration, making it suitable for applications where precision is critical.

5. Multi-Point Calibration

For applications requiring high precision across multiple loads, consider a multi-point calibration (often five points).

1. Apply weights at various increments (0%, 20%, 40%, 60%, 80%, 100%).

2. Record each output reading.

3. Use these readings to create a calibration curve that adjusts for linearity and hysteresis.

Multi-point calibration is ideal for complex systems where loads vary significantly during operation.

Best Practices for Calibration

To ensure successful calibration of your Omega load cell, adhere to these best practices:

- Regular Calibration: Schedule calibrations based on usage frequency and criticality of measurements. For example, if your application involves heavy usage or critical safety measurements, consider calibrating more frequently.

- Documentation: Keep detailed records of each calibration session, including dates, methods used, and results. This documentation can be invaluable for troubleshooting discrepancies later on.

- Environmental Control: Perform calibrations in controlled environments to minimize external influences on measurements such as temperature fluctuations or vibrations.

- Use Quality Weights: Ensure that all calibration weights are certified and traceable to national standards to guarantee their accuracy.

Troubleshooting Common Issues

If you encounter discrepancies during calibration, consider these common issues:

- Mechanical Wear: Inspect for signs of wear on the load cell or mounting hardware. Over time, components may loosen or degrade, affecting performance.

- Environmental Factors: Check if temperature or humidity levels have changed significantly since last calibration; even small changes can impact readings.

- Electrical Interference: Ensure that all electrical connections are secure and free from interference from other electronic devices nearby.

Advanced Calibration Techniques

For users seeking even greater accuracy or working in specialized fields, advanced techniques may be employed:

Dynamic Calibration

Dynamic calibration involves applying loads that change over time rather than static weights. This method simulates real-world conditions more accurately and can be particularly useful in applications like robotics or material testing where loads fluctuate rapidly.

Software Calibration Tools

Many modern Omega load cells come equipped with software that can assist in calibration processes by automating data collection and analysis. Utilizing such tools can enhance accuracy by reducing human error during manual recording and calculations.

Conclusion

Calibrating an Omega load cell is crucial for maintaining accurate measurements in various applications. By following systematic procedures and best practices outlined in this guide, you can ensure that your load cell operates reliably over time. Regular maintenance and careful attention to detail during calibration will enhance performance and extend lifespan.

calibrate hydraulic load cell_1

FAQ

1. Why is regular calibration necessary for Omega load cells?

Regular calibration ensures that measurements remain accurate over time, compensating for factors like mechanical wear or environmental changes.

2. What is the difference between one-point and two-point calibration?

One-point calibration adjusts only at a single known weight, while two-point calibration adjusts at both zero and full-scale weights for greater accuracy across a range.

3. How often should I calibrate my Omega load cell?

The frequency of calibration depends on usage intensity; however, annual calibrations are commonly recommended for most applications.

4. Can I perform calibration myself?

Yes, as long as you have the necessary tools and follow proper procedures; however, professional services may be advisable for critical applications.

5. What should I do if my readings are inconsistent after calibration?

Investigate potential issues such as mechanical wear, improper installation, or environmental factors affecting performance.

Table of Content list

Related Products

Related Products

content is empty!

Motor Customization Guide

Please provide your detailed requirements, and our engineers will offer you the optimal solution tailored to your specific application.

Contact Us

For over a decade, FIBOS has been engaged in manufacturing micro force sensor and load cells. We are proud to support all of our customers, regardless of their size.

 Load cell capacity range from 100g to 1000ton
 Reduction delivery time by 40%.
Contact us

You can easily upload your 2D/3D CAD design files, and our sales engineering team will provide you with a quote within 24 hours.

ABOUT US

Fibos specializes in research, development and production of weighing force sensor.
SERVICE & CALIBRATION
​Calibration service is NIST and in compliance with ISO 17025.