 nickinfo@fibos.cn  |     0086 18921011531

How To Measure Strain Gauge Load Cell?

Views: 222     Author: Tina     Publish Time: 2024-11-12      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Content Menu

Introduction

Understanding Strain Gauge Load Cells

>> What is a Strain Gauge?

>> How Load Cells Work

Setting Up a Strain Gauge Load Cell

>> Required Equipment

>> Installation Steps

Calibration of Strain Gauge Load Cells

>> Calibration Procedure

Measuring with Strain Gauge Load Cells

>> Taking Measurements

Applications of Strain Gauge Load Cells

>> Industrial Weighing

>> Structural Monitoring

>> Automotive Testing

>> Medical Applications

>> Research and Development

Troubleshooting Common Issues

>> Signal Noise

>> Non-Linearity

>> Temperature Effects

Conclusion

Related Questions

>> 1. What are the main components of a strain gauge load cell?

>> 2. How do I know if my load cell is calibrated correctly?

>> 3. Can I use a strain gauge load cell for dynamic measurements?

>> 4. What factors can affect the accuracy of load cell measurements?

>> 5. How often should I calibrate my load cell?

Introduction

Strain gauge load cells are essential devices used in various applications to measure force, weight, and pressure. They operate on the principle of strain measurement, where the deformation of a material under load is converted into an electrical signal. This article will provide a comprehensive guide on how to measure strain gauge load cells, covering their working principles, setup, calibration, and practical applications.

Understanding Strain Gauge Load Cells

What is a Strain Gauge?

A strain gauge is a sensor that detects the amount of deformation or strain in an object. When a force is applied to an object, it deforms, and the strain gauge measures this deformation. The gauge consists of a thin wire or foil arranged in a grid pattern, which changes its electrical resistance when stretched or compressed. This change in resistance is proportional to the amount of strain experienced by the gauge.

How Load Cells Work

Load cells are transducers that convert a force into an electrical signal. A strain gauge load cell typically consists of a metal body that deforms under load. The strain gauges are bonded to the metal body, and as the body deforms, the strain gauges also deform, changing their resistance. This change in resistance is measured and converted into an electrical signal that corresponds to the applied load.

strain gauge vs load cell5

Setting Up a Strain Gauge Load Cell

Required Equipment

To measure a strain gauge load cell, you will need the following equipment:

1. Strain Gauge Load Cell: The primary sensor for measuring force.

2. Signal Conditioning Circuit: This amplifies the small electrical signal from the load cell.

3. Data Acquisition System: A device to collect and analyze the data from the load cell.

4. Power Supply: To power the signal conditioning circuit and data acquisition system.

5. Calibration Weights: Known weights to calibrate the load cell.

Installation Steps

1. Mounting the Load Cell: Secure the load cell to a stable surface or structure where the force will be applied. Ensure that it is aligned correctly to avoid measurement errors. The mounting should be rigid to prevent any movement that could affect the readings.

2. Wiring the Load Cell: Connect the load cell to the signal conditioning circuit. Typically, load cells have four wires: two for the excitation voltage and two for the output signal. Follow the manufacturer's wiring diagram for correct connections. Proper wiring is crucial for accurate measurements and to prevent damage to the load cell.

3. Connecting the Signal Conditioning Circuit: Connect the output of the load cell to the input of the signal conditioning circuit. This circuit will amplify the signal for better accuracy. Ensure that the signal conditioning circuit is compatible with the load cell specifications.

4. Setting Up the Data Acquisition System: Connect the output of the signal conditioning circuit to the data acquisition system. This system will record the measurements for analysis. Make sure the data acquisition system is configured to read the type of signal output from the load cell.

5. Powering the System: Ensure that all components are powered correctly. Check the voltage levels to avoid damaging the equipment. A stable power supply is essential for consistent performance.

Calibration of Strain Gauge Load Cells

Calibration is crucial for ensuring accurate measurements. Here's how to calibrate a strain gauge load cell:

Calibration Procedure

1. Zeroing the Load Cell: Before applying any weight, ensure that the load cell reads zero. This step is essential to eliminate any offset errors. If the load cell does not read zero, adjust it accordingly.

2. Applying Known Weights: Gradually apply known weights to the load cell. Start with the lowest weight and increase it incrementally. Record the output signal for each weight. This step helps in establishing a relationship between the applied load and the output signal.

3. Creating a Calibration Curve: Plot the recorded output signals against the known weights. This graph will help you visualize the relationship between the applied load and the output signal. A linear relationship is typically expected, indicating that the load cell is functioning correctly.

4. Calculating Calibration Factors: Use the slope of the calibration curve to determine the calibration factor. This factor will be used to convert the output signal into a measurable force. The calibration factor is critical for accurate measurements in practical applications.

5. Verifying Calibration: After establishing the calibration curve, apply a few weights again to verify that the load cell provides accurate readings. If discrepancies are found, recalibrate the load cell as necessary.

strain gauge load cell

Measuring with Strain Gauge Load Cells

Taking Measurements

Once the load cell is calibrated, you can start taking measurements. Here's how to do it:

1. Prepare the Load Cell: Ensure that the load cell is properly installed and calibrated. Double-check all connections and settings before proceeding.

2. Apply the Load: Gradually apply the load you wish to measure. Avoid sudden impacts, as they can cause measurement errors. The load should be applied evenly to prevent any side forces that could affect the readings.

3. Record the Output: Monitor the output signal from the data acquisition system. This signal will correspond to the applied load. Make sure to record the readings at stable conditions.

4. Convert the Signal: Use the calibration factor to convert the output signal into a measurable force or weight. This conversion is essential for interpreting the data accurately.

5. Repeat Measurements: For accuracy, repeat the measurements several times and calculate the average. This practice helps to minimize random errors and improve reliability.

Applications of Strain Gauge Load Cells

Strain gauge load cells are widely used in various industries due to their accuracy and reliability. Here are some common applications:

Industrial Weighing

Load cells are extensively used in industrial scales for weighing products, materials, and equipment. They provide precise measurements essential for inventory management and quality control. In manufacturing, accurate weight measurements are critical for ensuring product consistency and compliance with regulations.

Structural Monitoring

In civil engineering, strain gauge load cells are used to monitor the structural integrity of buildings, bridges, and dams. They help detect any changes in load or stress that could indicate potential failures. Continuous monitoring can prevent catastrophic failures and ensure public safety.

Automotive Testing

Load cells are used in automotive testing to measure forces during crash tests, performance evaluations, and component testing. This data is crucial for improving safety and performance. Engineers rely on load cell measurements to design safer vehicles and optimize performance characteristics.

Medical Applications

In the medical field, load cells are used in various devices, including hospital beds and scales, to monitor patient weight and ensure proper care. Accurate weight measurements are vital for patient management and treatment plans.

Research and Development

Load cells are essential in research laboratories for experiments requiring precise force measurements. They are used in material testing, robotics, and biomechanics. Researchers utilize load cells to gather data that informs product development and scientific studies.

Troubleshooting Common Issues

Signal Noise

One common issue with strain gauge load cells is signal noise, which can lead to inaccurate measurements. To minimize noise, ensure that all connections are secure and that the load cell is properly shielded from electromagnetic interference. Using a high-quality signal conditioning circuit can also help reduce noise.

Non-Linearity

Non-linearity in load cell measurements can occur due to improper calibration or mechanical issues. If the output does not follow a linear relationship with the applied load, recalibrate the load cell and check for any mechanical binding or misalignment.

Temperature Effects

Temperature changes can affect the performance of strain gauge load cells. It is essential to use load cells with temperature compensation features or to conduct measurements in a controlled environment to minimize temperature-related errors.

Conclusion

Measuring strain gauge load cells is a straightforward process that involves understanding their working principles, proper setup, calibration, and taking accurate measurements. With their wide range of applications, strain gauge load cells play a vital role in various industries, ensuring safety, efficiency, and quality. By following the steps outlined in this article, you can effectively measure and utilize strain gauge load cells in your projects.

strain gauge load cell 2

Related Questions

1. What are the main components of a strain gauge load cell?

The main components of a strain gauge load cell include the metal body, strain gauges, a signal conditioning circuit, and a data acquisition system. The metal body deforms under load, while the strain gauges measure this deformation and convert it into an electrical signal.

2. How do I know if my load cell is calibrated correctly?

To determine if your load cell is calibrated correctly, apply known weights and compare the output signal to the expected values. If the readings match the known weights within an acceptable range, the load cell is calibrated correctly.

3. Can I use a strain gauge load cell for dynamic measurements?

Yes, strain gauge load cells can be used for dynamic measurements, but it is essential to select a load cell designed for dynamic applications. These load cells are built to handle rapid changes in load and provide accurate measurements in dynamic conditions.

4. What factors can affect the accuracy of load cell measurements?

Factors that can affect the accuracy of load cell measurements include temperature variations, mechanical misalignment, signal noise, and improper calibration. Ensuring proper installation and calibration can help mitigate these issues.

5. How often should I calibrate my load cell?

The frequency of calibration depends on the application and the environment in which the load cell is used. It is generally recommended to calibrate load cells at least once a year or whenever there are significant changes in the operating conditions or after maintenance.

Table of Content list

Related Products

Related Products

content is empty!

Motor Customization Guide

Please provide your detailed requirements, and our engineers will offer you the optimal solution tailored to your specific application.

Contact Us

For over a decade, FIBOS has been engaged in manufacturing micro force sensor and load cells. We are proud to support all of our customers, regardless of their size.

 Load cell capacity range from 100g to 1000ton
 Reduction delivery time by 40%.
Contact us

You can easily upload your 2D/3D CAD design files, and our sales engineering team will provide you with a quote within 24 hours.

ABOUT US

Fibos specializes in research, development and production of weighing force sensor.
SERVICE & CALIBRATION
​Calibration service is NIST and in compliance with ISO 17025.

PRODUCTS

Customized Load Cell

SOLUTION

Automotive Testing

COMPANY

 Contact:

 Phone: +86 18921011531

 Email: nickinfo@fibos.cn

 Add: 12-1 Xinhui Road, Fengshu Industrial Park, Changzhou, China

Copyright © Fibos Measurement Technology (CHANGZHOU) Co., Ltd. Sitemap