Content Menu

Introduction

Understanding Load Cells: Types and Applications

>> Common Types of Load Cells

>> Applications Across Industries

Proper Load Cell Mounting Techniques

>> 1. Prepare the Mounting Surface

>> 2. Align the Load Cell

>> 3. Use Appropriate Mounting Hardware

>> 4. Consider Environmental Factors

>> 5. Implement Overload Protection

Load Cell Wiring and Connection

>> 1. Understand Wire Color Codes

>> 2. Use Shielded Cables

>> 3. Avoid Tension on Wires

>> 4. Seal Connections

Load Cell Calibration Process

>> 1. Zero Balancing

>> 2. Span Calibration

>> 3. Linearity Check

>> 4. Temperature Compensation

>> 5. Documentation

Troubleshooting Load Cell Issues

>> 1. Drift in Readings

>> 2. Nonlinearity

>> 3. Noise in Signal

Maintaining Load Cell Accuracy and Precision

>> 1. Regular Inspections

>> 2. Cleaning

>> 3. Recalibration

>> 4. Environmental Control

Selecting the Right Load Cell for Your Application

>> 1. Capacity

>> 2. Accuracy Class

>> 3. Environmental Considerations

>> 4. Output Signal

>> 5. Mounting Options

Conclusion

Frequently Asked Questions

>> Q1: How often should I calibrate my load cells?

>> Q2: Can I install a load cell myself, or should I hire a professional?

>> Q3: What should I do if my load cell readings are inconsistent?

>> Q4: How do I protect my load cells from overloading?

>> Q5: Can load cells be used in explosive or hazardous environments?

Introduction

Load cells are crucial components in various industries, from manufacturing and logistics to agriculture and pharmaceuticals. These precision instruments are designed to convert force into measurable electrical signals, enabling accurate weight measurements in a wide range of applications. However, the effectiveness of a load cell heavily depends on its proper installation and mounting. In this comprehensive guide, we'll explore the intricacies of load cell mounting, wiring, and maintenance to help you achieve optimal performance in your weighing systems.

Understanding Load Cells: Types and Applications

Before delving into the mounting process, it's essential to understand the different types of load cells and their specific applications. This knowledge will help you select the right load cell for your needs and ensure proper installation.

Common Types of Load Cells

1. Strain Gauge Load Cells: These are the most widely used type, utilizing strain gauges to measure deformation caused by applied force.

2. Hydraulic Load Cells: Ideal for harsh environments, these cells use fluid pressure to measure force.

3. Pneumatic Load Cells: These use air pressure and are suitable for applications requiring intrinsic safety.

4. Capacitive Load Cells: Known for their high accuracy and stability, these cells measure changes in electrical capacitance.

5. Piezoelectric Load Cells: Best for dynamic force measurements, these cells generate an electrical charge proportional to the applied force.

Applications Across Industries

Load cells find applications in various sectors:

- Manufacturing: Quality control, parts counting, and process monitoring

- Transportation: Vehicle weighing, aircraft weight and balance systems

- Agriculture: Grain storage, livestock weighing, and yield monitoring

- Healthcare: Patient monitoring, pharmaceutical dispensing

- Retail: Point-of-sale systems, inventory management

Understanding your specific application will guide you in selecting the appropriate load cell and mounting method.

mount a load cell1

Proper Load Cell Mounting Techniques

Correct mounting is crucial for ensuring accurate and reliable measurements. Here are the key steps and considerations for proper load cell installation:

1. Prepare the Mounting Surface

Ensure that the mounting surface is clean, level, and stable. Any unevenness or instability can lead to inaccurate readings. Use a spirit level to check for flatness and make necessary adjustments.

2. Align the Load Cell

Proper alignment is critical for accurate measurements. The load cell should be positioned so that the force is applied along its primary axis. Misalignment can cause off-axis loading, leading to errors and potential damage to the load cell.

3. Use Appropriate Mounting Hardware

Select mounting hardware that is compatible with your load cell and application. This may include bolts, washers, and mounting plates. Ensure that all hardware is properly tightened to the manufacturer's specifications.

4. Consider Environmental Factors

Take into account environmental conditions such as temperature fluctuations, humidity, and vibrations. Use appropriate shielding or protective enclosures when necessary to safeguard the load cell from harsh conditions.

5. Implement Overload Protection

Install mechanical stops or other protective measures to prevent overloading, which can damage the load cell and compromise accuracy.

Load Cell Wiring and Connection

Proper wiring is essential for accurate signal transmission and reliable performance. Follow these guidelines for load cell wiring:

1. Understand Wire Color Codes

Load cells typically use standardized color codes for their wiring. Common color codes include:

- Red: Excitation +

- Black: Excitation -

- Green: Signal +

- White: Signal -

Always consult the manufacturer's datasheet to verify the specific color codes for your load cell.

2. Use Shielded Cables

To minimize electromagnetic interference, use shielded cables for connecting the load cell to the indicator or data acquisition system. Properly ground the shield to reduce noise and improve signal quality.

3. Avoid Tension on Wires

Ensure that the wires are not under tension and have sufficient slack. Tension can affect the load cell's performance and potentially damage the connections.

4. Seal Connections

In environments with high humidity or exposure to liquids, use appropriate sealants to protect electrical connections from moisture ingress.

mount a load cell3

Load Cell Calibration Process

Calibration is crucial for maintaining accuracy and ensuring compliance with industry standards. Here's an overview of the calibration process:

1. Zero Balancing

Start by setting the zero point of the load cell system. This involves adjusting the output signal when no load is applied.

2. Span Calibration

Apply known weights across the load cell's range to establish the relationship between applied force and output signal. This step may require multiple iterations for optimal accuracy.

3. Linearity Check

Verify the linearity of the load cell's response across its entire range. Make adjustments as necessary to ensure consistent accuracy.

4. Temperature Compensation

For applications where temperature fluctuations are significant, perform calibration at different temperatures to account for thermal effects.

5. Documentation

Maintain detailed records of calibration procedures, results, and any adjustments made. This documentation is essential for quality control and regulatory compliance.

Troubleshooting Load Cell Issues

Even with proper installation and calibration, issues may arise. Here are some common problems and their potential solutions:

1. Drift in Readings

Possible causes:

- Temperature fluctuations

- Mechanical stress on the load cell

- Moisture ingressSolutions:

- Implement temperature compensation

- Check for proper mounting and alignment

- Improve environmental protection

2. Nonlinearity

Possible causes:

- Overloading

- Improper calibration

- Damaged load cellSolutions:

- Verify load cell capacity and usage

- Recalibrate the system

- Replace the load cell if necessary

3. Noise in Signal

Possible causes:

- Electromagnetic interference

- Poor grounding

- Loose connectionsSolutions:

- Improve shielding

- Check and correct grounding issues

- Inspect and secure all connections

Maintaining Load Cell Accuracy and Precision

To ensure long-term accuracy and reliability, consider the following maintenance practices:

1. Regular Inspections

Conduct visual inspections of load cells and mounting hardware periodically. Look for signs of wear, corrosion, or damage.

2. Cleaning

Keep load cells clean and free from debris. Use appropriate cleaning agents that won't damage the load cell or its protective coatings.

3. Recalibration

Perform regular recalibrations based on usage, environmental conditions, and industry standards. This helps maintain accuracy over time.

4. Environmental Control

Where possible, control the environment around the load cell to minimize exposure to extreme temperatures, humidity, and vibrations.

Selecting the Right Load Cell for Your Application

Choosing the appropriate load cell is crucial for optimal performance. Consider these factors when selecting a load cell:

1. Capacity

Ensure the load cell's capacity matches your application requirements, with an appropriate safety factor.

2. Accuracy Class

Select a load cell with an accuracy class suitable for your measurement needs and industry standards.

3. Environmental Considerations

Choose a load cell with appropriate IP ratings and materials for your operating environment.

4. Output Signal

Consider the compatibility of the load cell's output signal with your data acquisition system or indicator.

5. Mounting Options

Select a load cell with mounting options that suit your application and installation constraints.

Conclusion

Proper mounting and installation of load cells are critical for achieving accurate and reliable weight measurements in industrial applications. By following the guidelines outlined in this article, you can ensure optimal performance, longevity, and precision in your weighing systems.

Remember that each application is unique, and consulting with load cell manufacturers or experts can provide valuable insights tailored to your specific needs.

install a load cell2

Frequently Asked Questions

Q1: How often should I calibrate my load cells?

A1: The frequency of calibration depends on various factors, including usage, environmental conditions, and industry regulations. As a general rule, it's recommended to calibrate load cells at least once a year. However, in critical applications or harsh environments, more frequent calibrations may be necessary. Always consult your industry standards and manufacturer recommendations for specific guidance.

Q2: Can I install a load cell myself, or should I hire a professional?

A2: While it's possible to install a load cell yourself, especially for simpler applications, hiring a professional is often recommended for complex systems or critical measurements. Professional installers have the expertise to ensure proper alignment, wiring, and calibration, which are crucial for accurate performance. If you choose to install it yourself, carefully follow the manufacturer's instructions and consider seeking expert advice if you encounter any difficulties.

Q3: What should I do if my load cell readings are inconsistent?

A3: Inconsistent readings can be caused by various factors. Start by checking the mounting and alignment of the load cell to ensure it's properly installed. Verify that all connections are secure and free from corrosion. Inspect the load cell for any signs of physical damage. If these checks don't resolve the issue, consider recalibrating the system. If problems persist, consult with the manufacturer or a load cell specialist to diagnose and address the underlying cause.

Q4: How do I protect my load cells from overloading?

A4: Protecting load cells from overloading is crucial to prevent damage and maintain accuracy. Implement mechanical stops or bumpers that limit the maximum force applied to the load cell. Use load cell mounting kits designed with overload protection features. Additionally, incorporate electronic safeguards in your control system to alert operators or shut down processes when load limits are approached. Always select a load cell with a capacity that exceeds your maximum expected load, typically by a factor of 150% to 200%.

Q5: Can load cells be used in explosive or hazardous environments?

A5: Yes, load cells can be used in explosive or hazardous environments, but you must select specially designed intrinsically safe or explosion-proof load cells. These load cells are constructed to prevent the ignition of flammable gases or vapors. They often come with certifications such as ATEX, IECEx, or FM approvals. When using load cells in hazardous areas, it's crucial to follow all relevant safety regulations and ensure that the entire weighing system, including indicators and wiring, complies with the required safety standards for the specific environment.

Table of Content list

Related Products

Related Products

content is empty!

Motor Customization Guide

Please provide your detailed requirements, and our engineers will offer you the optimal solution tailored to your specific application.

Contact Us

For over a decade, FIBOS has been engaged in manufacturing micro force sensor and load cells. We are proud to support all of our customers, regardless of their size.

 Load cell capacity range from 100g to 1000ton
 Reduction delivery time by 40%.
Contact us

You can easily upload your 2D/3D CAD design files, and our sales engineering team will provide you with a quote within 24 hours.

ABOUT US

Fibos specializes in research, development and production of weighing force sensor.
SERVICE & CALIBRATION
​Calibration service is NIST and in compliance with ISO 17025.