How Do I Calibrate A Load Cell with A Load Cell Tester?

Views: 222     Author: Tina     Publish Time: 2024-12-13      Origin: Site

Inquire

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

Content Menu

Introduction

What is a Load Cell?

Importance of Calibration

Equipment Needed for Calibration

Step-by-Step Calibration Process

>> Step 1: Setting Up the Load Cell

>> Step 2: Initial Configuration

>> Step 3: Zero Balance Calibration

>> Step 4: Applying Known Weights

>> Step 5: Calibration Adjustment

>> Step 6: Verification

Best Practices for Load Cell Calibration

Additional Considerations During Calibration

>> Temperature Effects

>> Humidity Considerations

>> Mechanical Stability

Troubleshooting Common Issues

Conclusion

FAQ

>> 1. What is a Load Cell Tester?

>> 2. How often should I calibrate my load cell?

>> 3. What are common issues faced during calibration?

>> 4. Can I perform calibration without a Load Cell Tester?

>> 5. What should I do if my calibrated readings are still inaccurate?

Introduction

Calibrating a load cell is a crucial process in ensuring the accuracy and reliability of weight measurements in various applications, from industrial scales to laboratory testing. This article provides a comprehensive guide on how to calibrate a load cell using a load cell tester, including detailed steps, best practices, and troubleshooting tips.

calibration factor in load cell_4

What is a Load Cell?

A load cell is a type of transducer that converts force or weight into an electrical signal. The most common type of load cell used in weighing applications is the strain gauge load cell, which operates on the principle of measuring the deformation (strain) of a material when a load is applied. This deformation alters the resistance of the strain gauge, allowing for the calculation of the applied weight.

Importance of Calibration

Calibration ensures that the load cell provides accurate readings by comparing its output against known reference weights. Over time, factors such as mechanical wear, environmental conditions, and electrical interference can lead to inaccuracies in measurements. Regular calibration helps maintain the reliability and precision of load cells.

Equipment Needed for Calibration

Before starting the calibration process, gather the following equipment:

- Load Cell Tester: A device specifically designed to test and calibrate load cells.

- Reference Weights: Known weights that will be used for calibration.

- Computer with Calibration Software: Many modern load cell testers come with software to assist in the calibration process.

- Power Supply: Ensure that your load cell tester is adequately powered.

Step-by-Step Calibration Process

Step 1: Setting Up the Load Cell

1. Install the Load Cell: Ensure that the load cell is properly installed in its application setup. This may involve mounting it securely and connecting it to the load cell tester.

2. Connect to Load Cell Tester: Use appropriate cables to connect the load cell to the load cell tester. Follow the manufacturer's instructions for wiring.

Step 2: Initial Configuration

1. Power On: Turn on the load cell tester and ensure it is functioning correctly.

2. Select Configuration: Depending on your tester model, select whether you are using a 4-wire or 6-wire configuration.

3. Input Rated Output: Enter the rated output of your load cell (typically given in mV/V). For instance, if your load cell has a full-scale output of 2 mV/V, input this value into your tester.

load cell calibration1

Step 3: Zero Balance Calibration

1. Tare the Scale: With no weight applied, tare or zero out the scale on your load cell tester. This step ensures that any subsequent measurements are relative to zero.

2. Record Zero Output: Check and record the output reading from your tester; this should be close to zero.

Step 4: Applying Known Weights

1. Apply Reference Weights: Start by applying known weights incrementally (e.g., 10%, 20%, ..., up to 100% of capacity).

2. Record Readings: After each weight is applied, allow some time for stabilization before recording the output reading from your tester.

3. Repeat Measurements: For each weight applied, take multiple readings (at least two) to ensure consistency and accuracy.

Step 5: Calibration Adjustment

1. Calculate Calibration Factors: Using the recorded values from your known weights and their corresponding outputs, calculate any necessary calibration factors or adjustments needed for accuracy.

2. Burn Calibration Values: If your load cell tester allows it, burn these calibration values into the device's memory to ensure they are used in future measurements.

Step 6: Verification

1. Verify Calibration: After completing calibration adjustments, remove all weights and tare again. Then reapply known weights to verify that readings match expected values.

2. Document Results: Keep detailed records of all calibration data including dates, weights used, and results before and after calibration for future reference.

Best Practices for Load Cell Calibration

- Regular Intervals: Schedule regular calibration intervals based on usage frequency and application criticality—typically annually or biannually.

- Environmental Control: Conduct calibrations in stable environmental conditions to minimize external influences like temperature fluctuations or vibrations.

- Use Multiple Points: For improved accuracy, use multiple reference weights across the operational range of the load cell during calibration.

- Documentation: Maintain thorough documentation of all calibration processes for traceability and compliance with industry standards.

load cell calibration services6

Additional Considerations During Calibration

When calibrating a load cell with a load cell tester, there are several additional factors to consider:

Temperature Effects

Temperature can significantly affect both load cells and their readings. It's essential to perform calibrations at consistent temperatures or account for temperature variations in your calculations. Some advanced load cells come equipped with temperature compensation features that help mitigate these effects during operation.

Humidity Considerations

Humidity can also impact electronic components within a load cell setup. High humidity levels may cause corrosion or affect electrical connections over time. Ensure that your calibration environment is controlled for both temperature and humidity whenever possible.

Mechanical Stability

The physical setup where the load cell is mounted should be stable and free from vibrations during calibration. Vibrations can lead to fluctuating readings that may skew results during testing. Use vibration isolation pads if necessary to minimize disturbances.

Troubleshooting Common Issues

If you encounter issues during calibration, consider these troubleshooting steps:

- Inconsistent Readings: Check for loose connections or damaged cables between the load cell and tester.

- Drift Over Time: If readings drift significantly over time, consider recalibrating more frequently or inspecting for mechanical wear.

- Environmental Factors: Ensure that environmental conditions remain stable throughout the calibration process.

Conclusion

Calibrating a load cell using a load cell tester is essential for maintaining measurement accuracy in various applications. By following systematic steps—setting up properly, applying known weights, adjusting calibration factors, and verifying results—you can ensure reliable performance from your load cells over time. Regular maintenance and documentation will further enhance their longevity and accuracy.

test steering torque sensor_3

FAQ

1. What is a Load Cell Tester?

A Load Cell Tester is a specialized device designed to diagnose and calibrate strain-gage-based load cells by measuring parameters like bridge resistance and signal output quickly and efficiently.

2. How often should I calibrate my load cell?

Calibration frequency depends on usage; however, it is generally recommended to calibrate at least once a year or before critical measurements are taken.

3. What are common issues faced during calibration?

Common issues include inconsistent readings due to poor connections, drift caused by environmental changes or mechanical wear, and incorrect weight application methods leading to inaccurate results.

4. Can I perform calibration without a Load Cell Tester?

While it's possible to manually calibrate using known weights and basic tools, using a Load Cell Tester significantly simplifies and enhances accuracy during the process.

5. What should I do if my calibrated readings are still inaccurate?

If inaccuracies persist after calibration, inspect connections for damage or looseness, check environmental conditions affecting measurements, or consider replacing worn-out components within your system.

Table of Content list

Related Products

Related Products

content is empty!

Motor Customization Guide

Please provide your detailed requirements, and our engineers will offer you the optimal solution tailored to your specific application.

Contact Us

For over a decade, FIBOS has been engaged in manufacturing micro force sensor and load cells. We are proud to support all of our customers, regardless of their size.

 Load cell capacity range from 100g to 1000ton
 Reduction delivery time by 40%.
Contact us

You can easily upload your 2D/3D CAD design files, and our sales engineering team will provide you with a quote within 24 hours.

ABOUT US

Fibos specializes in research, development and production of weighing force sensor.
SERVICE & CALIBRATION
​Calibration service is NIST and in compliance with ISO 17025.