You are here: Home » Blog » Spoke & Pancake Load Cells: Types, Applications, and How to Choose

Spoke & Pancake Load Cells: Types, Applications, and How to Choose

Views: 0     Author: Site Editor     Publish Time: 2026-11-24      Origin: Site

facebook sharing button
twitter sharing button
line sharing button
wechat sharing button
linkedin sharing button
pinterest sharing button
whatsapp sharing button
kakao sharing button
snapchat sharing button
telegram sharing button
sharethis sharing button

 

Spoke and pancake load cells measure axial force in a compact, round body. They fit applications where the available height between an actuator, tool, or test fixture is limited. Start with how the machine applies force. A press that only pushes may use a compression-only model, while a test fixture that pulls and pushes needs a load cell and mounting hardware rated for both directions.

For a new machine, start with the force range and the tooling layout. For a replacement, start with the original model's drawing, calibration data, and electrical interface.

What Are Spoke and Pancake Load Cells?

· How Spoke, Pancake, and Shear Web Load Cells Overlap

Pancake describes the low-profile, round shape. Spoke describes the radial elements that connect a center hub to the outer body. Shear web refers to the thin sections that deform in shear under load. A round cell with radial shear webs can fit all three descriptions. Some low-capacity pancake designs use bending elements, so use the model drawing to confirm how it is built and loaded.

· How Force Travels from the Center Hub to the Outer Ring

In a typical spoke design, the tool applies axial force to the center hub. The radial elements carry that force to the outer ring, and the mounting base supplies the reaction. A fixture that touches both the hub and the outer ring can create a second load path. Part of the applied force can then bypass the sensing elements, reducing the measured force. In the FA120B compression example below, the loading adapter bears on the raised center boss and the sensor body is fastened to the mounting base.

01-fibos-fa120b-compression-load-path

Figure 1. FA120B under axial compression. The adapter loads the raised center boss, and the mounting base provides the reaction. Illustration based on the FIBOS installation drawing.

· How Strain Gauges Turn Deformation into a Force Signal

Bonded strain gauges change resistance as the sensing elements deform. A Wheatstone bridge turns those resistance changes into a small differential voltage. A rated output of 2 mV/V produces about 20 mV of signal change from zero load to rated load with 10 V excitation. The conditioner reads that signal and scales it to force using calibration data. NIST force calibration procedures

Which Designs Are Used for Compression or Tension?

· Compression-Only Designs with a Loading Button

A compression-only model with a central loading button suits a fixture that pushes on the specified contact surface. Check the drawing for the required mating surface and clearance around the button. If the press ram approaches at an angle or the tooling can shift under load, correct the guidance or use an approved loading accessory before relying on the reading.

· Center-Threaded Designs for Tension and Compression

A center-threaded model rated for both directions can connect to a threaded adapter or test fixture. The outer ring or specified base must provide the reaction in tension as well as compression. Check thread size, pitch, engagement depth, and the prescribed hub and base torques. The FIBOS FA120B is an example of a center-threaded tension and compression model. Use the drawing for the selected capacity when designing the adapter. FIBOS FA120B

The FA120B datasheet lists discrete rated capacity options from 0.1 to 30 t, non-linearity of ≤0.05% F.S., and an IP66 rating. Dimensions and center thread size vary by capacity.

02-fibos-fa120b-spoke-load-cell

Figure 2. FIBOS FA120B center-threaded tension and compression spoke load cell. Product graphic based on the catalog image.

Where Are Spoke and Pancake Load Cells Used?

· Press-Fit and Assembly Force Monitoring

Install the cell in the tool's force path to track insertion force. If the station measures displacement, synchronize the force and position channels so the controller can compare the force-displacement curve with the acceptance window. Check early contact and final seating separately when those events have different force limits.

· Materials Testing and Actuator Test Rigs

On a materials tester, the cell measures the force transmitted through the specimen fixtures. On an actuator test rig, it can measure push and pull forces when the cell and fixtures support both directions. Check fixture alignment and play, especially where the load reverses. If the test also reports displacement, account for fixture and machine deflection whenever they affect the displacement result.

· Cyclic Loading and Fatigue Testing

For endurance tests, give the supplier the minimum and maximum forces, whether the load reverses, the cycle frequency, and the expected cycle count. Compare that loading history with the fatigue rating for the selected model. The rated capacity and safe overload values describe different limits from the load a sensor can repeatedly sustain.

How Do You Choose the Right Spoke or Pancake Load Cell?

· Size the Capacity for Working Force, Peaks, and Load Cycles

Start with the maximum total force the cell sees in normal operation. Include any preload carried by the cell and check short peaks during contact, stopping, or reversal. Taring the display removes the preload from the displayed reading while the mechanical load remains on the cell. Check fault loads separately against the specified overload limits and the machine's protective measures.

· Check Measurement Error at the Lowest Working Force

Convert datasheet errors stated as a percentage of full scale into newtons. Then compare them with the smallest process change the machine needs to detect. Include the relevant effects of hysteresis, temperature, repeatability, electronics, and mounting in the installed error budget. Check the datasheet definition of combined error before adding separate allowances, since it may already include some of those terms.

· Check Available Height, Mounting Dimensions, and IP Rating

Measure the total space for the cell, base, loading adapter, fasteners, and cable bend. Check diameter, bolt circle, thread depth, and access for installation tools. Compare the IP rating and operating temperature with the actual environment. If oil, coolant, or cleaning agents can reach the assembly, confirm compatibility of the cell, cable, and connector with the fluids and cleaning method.

· Worked Example: Choosing a Load Cell for a Press-Fit Station

Assume a station monitors an early insertion feature at 100 N and then measures a maximum normal force of 1.8 kN. Both values include the tooling preload. The example allows up to ±5 N of installed measurement error at 100 N. Compare hypothetical 2 kN and 5 kN candidates, each with non-linearity of ±0.05% of full scale.

Rated capacity Capacity above the normal peak Non-linearity contribution Share of the 5 N error allowance
2 kN 0.2 kN ±1.0 N 20%
5 kN 3.2 kN ±2.5 N 50%

The 2 kN candidate leaves more of the error budget available at 100 N, while the 5 kN candidate leaves more capacity above the normal peak. Keep the 2 kN option under consideration if measured transients and expected cycle loads fit its ratings. For the 5 kN option, check whether the remaining error allowance covers the rest of the measurement chain. Verify the selected assembly with a reference load at 100 N and near 1.8 kN, and check peak capture at the intended press speed.

How Do You Mount the Load Cell and Control Off-Axis Loads?

· Check Base Flatness, Bolt Pattern, and Mounting Torque

Use the model drawing to identify the support surface and the areas that must remain clear. Clean the mating surfaces and check flatness, stiffness, and hole alignment before tightening. Use the fastener grade, thread engagement, tightening sequence, and torque specified for the exact model and capacity. For the FIBOS FA120B, start with the installation drawing for the selected capacity and confirm any fastening details the drawing leaves open with FIBOS. Record the unloaded output before and after mounting so you can spot any change caused by the installation. FIBOS FA120B installation drawing

· Align the Load Axis and Limit Side Loads and Bending Moments

Align the actuator, loading point, and load cell axis. An axial force of 1 kN applied 5 mm off-center introduces a bending moment of 5 N·m. Check that moment against the model's limit at the same axial load. If the tooling shifts during the stroke, improve guidance or use an approved alignment accessory. Check loaded alignment as well as the setup at rest.

03-centered-and-eccentric-load

Figure 3. The dashed line is the sensor centerline. An offset of 5 mm at 1 kN produces a moment of 5 N·m. Check allowable moments for the actual model and load combination.

How Do You Connect and Verify the Measurement System?

· Match the mV/V Output, Excitation, and Signal Conditioner

Check whether the cell has a raw bridge output or an amplified output. For a raw bridge, use a conditioner with compatible excitation voltage, input range, and wiring for the model's four- or six-wire connection. Set the conditioner and controller to the same force units and polarity. For press monitoring, verify the effective sample rate and filtering at the point where the controller evaluates the peak.

· Verify Zero and Check Known Loads After Installation

Use the production fixture, electronics, and filter settings throughout the verification. Apply traceable reference forces along the intended load axis and use project-defined tolerances for acceptance. NIST calibration of force transducers

  1. Record the raw offset in a defined reference condition. If tooling weight remains on the cell, record it before setting the operational zero.

  2. Apply reference forces near the lowest critical force, in the middle of the working range, and near the highest normal force. Record the reference and indicated values during loading and unloading. For bidirectional use, verify both directions.

  3. Repeat critical points and record the return to zero. Compare indication error, repeatability, and zero return with their acceptance limits. If the process relies on transient peaks, also verify peak capture under representative speed and loading conditions.

An electrical shunt check can verify the response of the bridge and electronics to a known simulated signal. Applying reference force also checks how the installed mechanics transmit load.

What Should You Check Before Replacing an Existing Load Cell?

· Compare the Original Drawing, Load Direction, and Electrical Interface

Compare drawings for overall height, bolt circle, center thread, support location, and cable exit. Check rated force, approved load directions, side-load and moment limits, and environmental rating. Then compare rated output, excitation, wiring pinout, and connector. Confirm these details against the exact capacity and version being ordered.

· Verify the Replacement Across the Machine's Working Range

After mounting, confirm polarity with a small known force and update the scale in the conditioner or controller using the replacement cell's calibration data. Run the installed-system checks, then compare the machine's low-force detection and production-speed peak readings with its acceptance criteria. For candidate models and current drawings, see the FIBOS spoke load cell range.

Frequently Asked Questions

1. Can a Pancake Load Cell Be Mounted Upside Down?

It can if the manufacturer permits that orientation and the drawing's support and load introduction requirements are met. Check how the fixture weight affects zero and occupies capacity. Verify the reading with a known load in the actual mounting position.

2. Can a Compression-Only Load Cell Measure Tension if It Has a Center Thread?

Use it for compression only. A center thread can provide a mounting point for a compression adapter. Tension requires a cell rated and calibrated for that direction, plus a mounting assembly designed to carry the tensile force.

3. How Much Side Load Can a Spoke Load Cell Tolerate?

Use the side-load limit for the exact model and capacity. Ask whether the published value is a mechanical limit or a condition tied to measurement error, and how it applies when axial force and bending moment occur together. If the documentation gives no limit, obtain confirmation before approving the design.

4. Can a Pancake Load Cell Capture a Short Force Peak?

It depends on the peak duration and the response of the mounted sensor, fixture, conditioner, and acquisition system. A slow filter can reduce the indicated peak even at a high sample rate. Check peak magnitude and timing against a suitable reference under representative dynamic conditions. NIST dynamic force measurement

5. Why Does the Zero Reading Change After the Mounting Bolts Are Tightened?

Tightening can introduce strain if the base is uneven, the bolts are loaded unevenly, or the fixture contacts a surface intended to remain clear. Compare the recorded zero shift with the model's installation guidance. Check the mating surfaces, clearances, and tightening procedure before resetting zero and repeating the reference-load checks.

Contact us
LET’S WORK THROUGH IT

What are you working on?

Tell us what you need to measure.We’ll help you explore the next step.
Helpful to include
Measurement range · Available space
Signal output · Operating conditions
Drawings, specifications or application photos. Preview form · Nothing is sent or uploaded.
Products
Applications
Why Fibos
Links
© COPYRIGHT 2026 FIBOS MEASUREMENT TECHNOLOGY (CHANGZHOU) CO., LTD. ALL RIGHTS RESERVED.